Mã lỗi 03-160-00, 03-990-00 — Xerox Phaser 4620

Code: 03-160-00, 03-990-00

Description: HCF Communications Fault
Causes: 03-160-00 A communication error has occurred between the MCU Board and the HCF. 03-990-00 A communication error has occurred between the MCU Board and the HCF.
Remedy: • Lock the feeder to the HCF. • Reseat the IOT, Tray 3, Tray 4, on the HCF. • Check for obstructions blocking the option connections.
Cycle system power. The error message is displayed. Y↓ N→Complete. Remove the IOT and installed feeders from the HCF. Check the HCF option harness. The harness is undamaged. Y↓ N→Replace the damaged option harness. Check feeder option harness continuity for all feeders. The harnesses are undamaged. Y↓ N→Replace the damaged option harness. Check the IOT Lower Option Harness. The harness is undamaged. Y↓ N→Replace the Lower Option Harness. Replace these components in order until the error is corrected. 1. HCF Control Board, PL 7.25 Item 18 2. MCU Board, PL 3.10 Item 3

← Xem tất cả mã lỗi Xerox Phaser 4620