Code: 08-110-00
Description: Feed Motor Failure
Causes: The Feed Drive Assembly failed to rotate.
Remedy: • Check all interlocks. • Check for obstructions blocking motor rotation.
Cycle system power. The error message is displayed. Y↓ N→Complete. Select dC330 code 08-920 to test the Feed Drive. The Feed Drive Assembly rotates (on/ off). Y↓ N→Remove the Right Cover and reseat CN12 on the MCU Board, then retest. The Feed Drive Assembly rotates. Y↓ N→Manually rotate the feed motor. The motor rotates freely. Y↓ N→Check for obstructions in the media path. If no obstructions are present, replace the Feed Drive Assembly. Replace the Feed Drive Assembly. Reassemble and perform SCP 6 Final Actions. Replace these components in order until the error is corrected. 1. MCU Board, PL 3.10 Item 3 2. HVPS, PL 1.10 Item 1
Cycle system power. The error message is displayed. Y↓ N→Complete. Select dC330 code 08-920 to test the Feed Drive. The Feed Drive Assembly rotates (on/ off). Y↓ N→Remove the Right Cover and reseat CN12 on the MCU Board, then retest. The Feed Drive Assembly rotates. Y↓ N→Manually rotate the feed motor. The motor rotates freely. Y↓ N→Check for obstructions in the media path. If no obstructions are present, replace the Feed Drive Assembly. Replace the Feed Drive Assembly. Reassemble and perform SCP 6 Final Actions. Replace these components in order until the error is corrected. 1. MCU Board, PL 3.10 Item 3 2. HVPS, PL 1.10 Item 1