Code: 08-650-00
Description: Duplex Unit Not Installed
Causes: Duplex Unit Detect Sensor indicates the Duplex Unit is not installed.
Remedy: • Reseat the Duplex Unit. • Check for obstructions blocking the sensor.
Check the Duplex Unit where the housing actuates the Duplex Unit Detect Sensor. The actuator area is undamaged. Y↓ N→Replace the Duplex Unit. Check the Duplex Unit Detect Sensor for damage or disconnection. The sensor is connected and undamaged. Y↓ N→Reconnect or replace the sensor. Check the Duplex Unit Detect Sensor. The sensor is connected and undamaged. Y↓ N→Replace the sensor , then retest. The error is displayed. Y↓ N→Remove the Left Cover and reseat CN1 on the Joint Board, then retest. The sensor signal changes. Y↓ N→Replace the Joint Board. Reassemble and perform SCP 6 Final Actions. Reassemble and perform SCP 6 Final Actions. Replace the MCU Board.
Check the Duplex Unit where the housing actuates the Duplex Unit Detect Sensor. The actuator area is undamaged. Y↓ N→Replace the Duplex Unit. Check the Duplex Unit Detect Sensor for damage or disconnection. The sensor is connected and undamaged. Y↓ N→Reconnect or replace the sensor. Check the Duplex Unit Detect Sensor. The sensor is connected and undamaged. Y↓ N→Replace the sensor , then retest. The error is displayed. Y↓ N→Remove the Left Cover and reseat CN1 on the Joint Board, then retest. The sensor signal changes. Y↓ N→Replace the Joint Board. Reassemble and perform SCP 6 Final Actions. Reassemble and perform SCP 6 Final Actions. Replace the MCU Board.