Code: 09-230-00, 09-250-00
Description: Toner Cartridge CRUM Write/Read Error
Causes: 09-230-00 Fail to write the information to the Toner Cartridge CRUM. 09-230-00 Fail to read the information from the Toner Cartridge CRUM.
Remedy: • Cycle system power. • Replace the Toner Cartridge.
Check the Toner Cartridge CRUM connection. The connection is clean and undamaged. Y↓ N→Cycle system power. The error message is displayed. Y↓ N→Reassemble and perform SCP 6 Final Actions. Replace the Toner Cartridge. The error message is displayed. Y↓ N→Reassemble and perform SCP 6 Final Actions. Remove the Right Cover and reseat CN2 on the MCU Board. The error message is displayed. Y↓ N→Reassemble and perform SCP 6 Final Actions. Replace the MCU Board. Remove the Left Cover and check the toner CRUM harness. The harness is connected and undamaged. Y↓ N→Repair or reconnect the harness. Replace these components in order until the error is corrected. 1. Joint Board, PL 9.15 Item 7 2. MCU Board, PL 3.10 Item 3
Check the Toner Cartridge CRUM connection. The connection is clean and undamaged. Y↓ N→Cycle system power. The error message is displayed. Y↓ N→Reassemble and perform SCP 6 Final Actions. Replace the Toner Cartridge. The error message is displayed. Y↓ N→Reassemble and perform SCP 6 Final Actions. Remove the Right Cover and reseat CN2 on the MCU Board. The error message is displayed. Y↓ N→Reassemble and perform SCP 6 Final Actions. Replace the MCU Board. Remove the Left Cover and check the toner CRUM harness. The harness is connected and undamaged. Y↓ N→Repair or reconnect the harness. Replace these components in order until the error is corrected. 1. Joint Board, PL 9.15 Item 7 2. MCU Board, PL 3.10 Item 3