Mã lỗi 10-100-00, 10-200-00, 10-300-00 — Xerox Phaser 4620

Code: 10-100-00, 10-200-00, 10-300-00

Description: Fuser Thermal Errors
Causes: 10-100-00 Open Fuser Circuit Error. The Fuser did not warm up during operation. Thermistor did not connect or contact point is not coupled tightly in power on. 10-200-00 Fuser Low Heat Error. The Fuser could not reach proper temperature, or improper thermistor reading. 10-300-00 Fuser Overheat Error. The Fuser temperature has risen to a very high degree. If the temperature of the Heat Roller increases above the toner-fusing-temperature, parts of Fuser may be thermally degraded. The thermistor is disconnected or providing erroneous readings.
Remedy: • Reseat the Fuser. • Check for obstructions or damage to the Fuser connection.
Check the Fuser connector for dirt or damage. The connector is clean and undamaged. Y↓ N→Clean or repair the connection. Select dC330 codes 10-200 and 10-210 to check Heat Roller temperature readings. The readings are within the operating range. Y↓ N→Replace the Fuser Thermistor. The error message is displayed. Y↓ N→Reassemble and perform SCP 6 Final Actions. Replace the Fuser. Remove the Right Cover and bottom fuser bracket, Figure 1. Check the Fuser Drive Board, MCU Board (CN10) and HVPS connections. The harnesses are connected and undamaged. Y↓ N→Repair or connect the harness. Replace these components in order until the error is corrected. 1. Fuser, PL 10.10 Item 1 2. Fuser Drive Board, PL 1.15 Item 2 3. MCU Board, PL 3.10 Item 3

← Xem tất cả mã lỗi Xerox Phaser 4620

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie