Code: 12-915-00
Description: Diverter Fault
Causes: The Finisher IOT exit gate diverter could not find home position as indicated by the Finisher Exit Gate Sensor.
Remedy: • Open, then close the Finisher Rear Door. • Cycle system power.
Cycle system power. The error message is displayed. Y↓ N→Complete. Select dC330 code 12-900 to test the Exit Gate Sensor. The sensor signal changes (high/ low). Y↓ N→Remove the Finisher, GP 14 to check the condition of the Finisher option connector and harness. The connector and harness are undamaged. Y↓ N→Repair the harness. Remove the Finisher right cover and reseat P/J1 on the Finisher Control Board. The error message is displayed. Y↓ N→Reassembly and perform SCP 6 Final Actions. Replace the Exit Gate Sensor. The error message is displayed. Y↓ N→Reassembly and perform SCP 6 Final Actions. Replace the Mailbox Control Board. Replace these components in order until the error is corrected. 1. IOT Upper Option Harness, PL 10.30 Item 24 2. MCU Board, PL 3.10 Item 3
Cycle system power. The error message is displayed. Y↓ N→Complete. Select dC330 code 12-900 to test the Exit Gate Sensor. The sensor signal changes (high/ low). Y↓ N→Remove the Finisher, GP 14 to check the condition of the Finisher option connector and harness. The connector and harness are undamaged. Y↓ N→Repair the harness. Remove the Finisher right cover and reseat P/J1 on the Finisher Control Board. The error message is displayed. Y↓ N→Reassembly and perform SCP 6 Final Actions. Replace the Exit Gate Sensor. The error message is displayed. Y↓ N→Reassembly and perform SCP 6 Final Actions. Replace the Mailbox Control Board. Replace these components in order until the error is corrected. 1. IOT Upper Option Harness, PL 10.30 Item 24 2. MCU Board, PL 3.10 Item 3