Code: 042 358
Description: IOT Fan Motor Failure The following fans were stopped. MIDDLE FAN, REAR FAN, SIDE FAN
Causes: MIDDLE FAN (PL10.1.2) REAR FAN (PL10.1.4) SIDE FAN (PL10.1.5) HARNESS ASSY SIDE FAN (PL10.1.6) KIT BASE ASSY INTERLOCK (PL12.1.1) HARNESS ASSY INTERLOCK (PL12.1.4) (The KIT BASE ASSY INTERLOCK is the unit for replacement) MCU PWB (PL11.1.3)
Remedy: 1 Check the open/close status of the Front Cover and Top Cover Are the Front Cover and Top Cover completely closed? (Is the Interlock Switch pressed securely?) Go to Step 2 Close the Cover (Press the Interlock Switch securely) 2 Check the Fan operation Enter the CE mode and execute the following menus to check the Fan operation. IOT Diag / Digital Output / DO-2f Are the Fans operating normally? Replace the MCU PWB Go to Step 3 3 Check the connections of the Fans Check the connection between each Fan and the MCU PWB. Are P/J14, P/J15, P/J16, and P/J1610 connected securely? Go to Step 4 Connect P/J14, P/J15, P/J16, and P/J1610 securely 4 Check the conductivity of the HARNESS ASSY SIDE FAN Is the wire between P/J1610 <=> P/J16 conducting properly? Go to Step 5 Replace the HARNESS ASSY SIDE FAN 5 Check the voltage supply to the SIDE FAN Measure the voltage between MCU PWB GND <=> P/J16-1 Pin. Close the Interlock Switch (HARNESS ASSY INTERLOCK) before checking. Is there a voltage (approx. +24VDC) output? Go to Step 6 6 Check the voltage supply to the MIDDLE FAN Measure the voltage between MCU PWB GND <=> P/J14-1 Pin. Close the Interlock Switch (HARNESS ASSY INTERLOCK) before checking. Is there a voltage (approx. +24VDC) output? Go to Step 7 7 Check the voltage supply to the REAR FAN Measure the voltage between MCU PWB GND <=> P/J15-1 Pin. Close the Interlock Switch (HARNESS ASSY INTERLOCK) before checking. Is there a voltage (approx. +24VDC) output? Go to Step 8 8 Check after the replacement of SIDE FAN Replace the SIDE FAN. Does an error occur? Go to Step 9 Procedure is complete