Code: E4-3, E4-5
Description: Jam at E - E4-3 Exit 2 Area Jam Paper did not pass the Exit 2 Exit Sensor located behind Door E on time. • Jam at E - E4-3 Exit 2 Area Jam • Jam at A - E4-5 Exit 2 Area Jam
Causes: • Exit 2 Exit Sensor • Exit 2 Motor • Exit 2 OCT Roller • Exit 2 FU Roller • Exit 2 Inv Roller • Exit PWB • Engine Control Board • LVPS
Remedy: 1 Check paper position at Door E. Is paper touching the Exit 2 Sensor? Remove the paper. Go to Step 2. 2 Check the FU Roller. Is the FU Roller worn or contaminated with paper dust? Clean or replace the FU Roller. Go to Step 3. 3 Check the drive transmission. Does the FU Roller and gears rotate smoothly? Go to Step 4. Restore proper operation. 4 Check the Inv Roller. Is the INV Roller worn or contaminated with paper dust? Clean or replace the INV Roller. Go to Step 5. 5 Check the drive transmission. Does the INV Roller and gears rotate smoothly? Go to Step 6. Restore proper operation. 6 Check the OCT Roller. Is the OCT Roller worn or contaminated with paper dust? Clean or replace the OCT Roller. Go to Step 7. 7 Check the drive transmission. Does the OCT Roller and gears rotate smoothly? For E4-5: Go to Step 8. For E4-3: Go to Step 9. Restore proper operation. 8 For E4-5 Only: Test Exit 2 Gate Solenoid. Run the Service Diagnostics Exit 2 Gate Solenoid test. Does the Solenoid operate the Gate? Go to Step 9. Go to Step 10. 9 Test the Exit 2 Sensor. 1. Open Door E. 2. Run the Service Diagnostics Exit Sensor test. Does the sensor change state? For E4-5: Go to Step 10. For E4-3: Go to Step 12. Go to Step12. 10 For E4-5 Only: Check Exit 2 Solenoid. Check continuity on each wire between P/ J209 to P/J433. Is there continuity on each wire between P/ J209 to P/J433. Go to Step 11. Repair the wiring. 11 For E4-5 Only: Check for +24 V to the Exit 2 Gate Solenoid. Is there +24 V across P/J433-11 (+) <=> ground? Replace the Exit 2 Gate Solenoid. Replace the Exit PWB. 12 Check the Exit Sensor connection. Are P/J112, P/J606B, and P/J434 connected? Go to Step 13. Connect the sensor. 13 Check continuity between the Exit Sensor and Exit PWB. Is there continuity on each wire between P/ J112 <=> P/J434? Go to Step 14. Repair the wiring. 14 Check for +5 V at the Exit Sensor. Is there +5 V across the sensor connector’s P/J112-3 <=> ground? Replace the Exit 2 Sensor. Go to Step 15. 15 Check the connection between the Exit PWB and Engine Control Board. Are P/J431 and P/J421 connected? Go to Step 16. Connect P/J431 and P/J421. 16 Check continuity between the Exit PWB and the Engine Control Board. Is there continuity on each wire between P/ J431 <=> P/J421? Go to Step 17. Repair the wiring. 17 Check the connection between the Exit PWB and the LVPS. Are P/J430 and P/J526 connected? Go to Step 18. Connect P/J430 and P/J526. 18 Check continuity between the Exit PWB and the LVPS. Is there continuity on each wire between P/ J430 <=> P/J526? Go to Step 19. Repair the wiring. 19 Check for +24 V to the Exit PWB. Is there +24 V across P/J430-1 (+) <=> ground? Replace the Exit PWB. Replace the LVPS. 20 Test the Exit 2 Motor operation. Run the Service Diagnostics Exit 2 Output Motor tests. Does the Exit 2 Motor operate properly? Replace the Engine Control Board. Go to Step 21. 21 Check the Exit 2 Motor connection. Are P/J208, P/J606A and P/J433 connected? Go to Step 22. Connect P/J208, P/J606A and P/ J433. 22 Check continuity between the Exit 2 Motor and Exit PWB. Is there continuity on each wire between P/ J208 <=> P/J433? Go to Step 23. Repair the wiring. 23 Check for +24 V to the Exit 2 Motor. Is there +24 V across P208-5 (+) <=> ground? Replace the Exit 2 Motor. Go to Step 24. 24 Check the connection between the Exit PWB and Engine Control Board. Are P/J431 and P/J421 connected? Go to Step 25. Connect P/J431 and P/J421. 25 Check continuity between the Exit PWB and Engine Control Board. Is there continuity on each wire between P/ J431 <=> P/J421? Go to Step 26. Repair the wiring. 26 Check the connection between the Exit PWB and the LVPS. Are P/J430 and P/J526 connected? Go to Step 27. Connect P/J430 and P/J526. 27 Check continuity between the Exit PWB and the LVPS. Is there continuity on each wire between P/ J430 <=> P/J526? Go to Step 28. Repair the wiring. 28 Check for +24 V to the Exit PWB. Is there +24 V across P/J430-1 (+) <=> ground? Replace the Exit PWB. Replace the LVPS.