Code: H3-7
Description: Exit Unit Failure - H3-7 Exit Board Comm Failure Communications failure between the Engine Control Board and Exit PWB.
Causes: • Exit PWB • LVPS • Engine Control Board
Remedy: 1 Check the Exit PWB connection. Are P/J431 and P/J421 connected? Go to Step 2. Connect P/J431 and P/J421. 2 Check continuity between the Exit PWB and the Engine Control Board. 1. Disconnect P/J431 and P/J421. 2. Check for continuity at the following: • P/J431-1 <=> P/J421-8 • P/J431-2 <=> P/J421-7 • P/J431-3 <=> P/J421-6 • P/J431-4 <=> P/J421-5 • P/J431-5 <=> P/J421-4 • P/J431-6 <=> P/J421-3 • P/J431-7 <=> P/J421-2 • P/J431-8 <=> P/J421-1 Are these conductive? Go to Step 3. Repair the wiring. 3 Check the connection between the Exit PWB and the LVPS. Are P/J430 and P/J526 connected? Go to Step 4. Connect P/J430 and P/J526. 4 Check continuity between the Exit PWB and the LVPS. 1. Disconnect P/J430 and P/J526. 2. Check for continuity at the following: • P/J430-3 <=> P/J526-6 • P/J430-4 <=> P/J526-5 • P/J430-1 <=> P/J526-8 • P/J430-2 <=> P/J526-7 Are these conductive? Go to Step 5. Repair the wiring. 5 Check for +24 V to the Exit PWB. Is there +24 V across P/J430-1 (+) <=> ground? Replace the Exit PWB. Replace the LVPS.