Mã lỗi H5-13 — Xerox Phaser 5400

Code: H5-13

Description: Stacker Lower Tray Failure - H5-13 Lower Tray Limit The Stacker Lower Tray descends beyond the specified lower limit position.
Causes: • Stack Height Sensor 1 • Stack Height Sensor 2 • Stacker Encoder Sensor • Finisher Main PWB • Main Sensor Harness • Elevator Motor
Remedy: 1 Check the Stacker Lower Tray vertical transport and belts for obstacles and deformation. Are there obstacles or belt wear in the vertical transport mechanism? Remove any obstacles. Go to Step 2. 2 Test the Stack Height Sensor 1 (top).Run the Service Diagnostics Stack Height 1 test. Does the sensor state change when the sensor is blocked? NOTE: Sensor requires a 10 second timeout between sensing events. Go to Step 8. Go to Step 3. 3 Check Stack Height Sensor 1 Sensor Harness connection. Are P/J8331 and P/J8302B connected? Go to Step 5. Connect and go to Step 4. 4 Print a Test Print. Does the error still occur? Go to Step 5. Problem solved. 5 Check Stack Height Sensor 1 Sensor Harness continuity. 1. Disconnect P/J8331 on the Main Sensor Harness, and P/J8302B on the Finisher Main PWB. 2. Check for continuity at the following: • P/J8331-5 <=> P/J8302B-1 • P/J8331-4 <=> P/J8302B-2 • P/J8331-3 <=> P/J8302B-3 • P/J8331-2 <=> P/J8302B-4 • P/J8331-1 <=> P/J8302B-5 Are these conductive? Go to Step 6. Repair the Stack Height Sensor 1 Sensor Harness. 6 Check for +5 V to Stack Height Sensor 1. Is there +5 V across J8302B-3 <=> J8302B- 1 on the Finisher Main PWB? Go to Step 7. Replace the Finisher Main PWB. 7 Check Stack Height Sensor 1 signal. Does the voltage across P8302B-2 <=> P8302B-1 on the Finisher Main PWB change when the sensor is blocked? Replace the Finisher Main PWB. Replace Stack Height Sensor 1. 8 Test the Stack Height Sensor 2 (bottom).Run the Service Diagnostics Stack Height Sensor 2 test. NOTE: Sensor requires a 10 second timeout between sensing events. Does the sensor state change when the sensor is blocked? Go to Step 14. Go to Step 9. 9 Check Stack Height Sensor 2 Sensor Harness connections. Are P/J8330 and P/J8302A connected? Go to Step 11. Connect and go to Step 10. 10 Print a Test Print. Does the error still occur? Go to Step 11. Problem solved 11 Check Stack Height Sensor 2 Sensor Harness continuity. 1. Disconnect P/J8330 on the harness, and P/J8302A on the Finisher Main PWB. 2. Check for continuity at the following: • P/J8330-5 <=> P/J8302A-16 • P/J8330-4 <=> P/J8302A-17 • P/J8330-3 <=> P/J8302A-18 • P/J8330-2 <=> P/J8302A-19 • P/J8330-1 <=> P/J8302A-20 Are these conductive? Go to Step 12. Repair the Stack Height Sensor 2 Harness. 12 Check for +5 V to Stack Height Sensor 2. Is there +5 V across J8302A-18 <=> J8302A-16 on the Finisher Main PWB? Go to Step 13. Replace the Finisher Main PWB. 13 Check Stack Height Sensor 2 signal. Does the voltage across P8302A-17 <=> P8302A-16 on the Finisher Main PWB change when the sensor is blocked? Replace the Finisher Main PWB. Replace Stack Height Sensor 2. 14 Test the Stacker Encoder Sensor. Run the Service Diagnostics Stacker Encoder Sensor test. Does the sensor state change when the Elevator Motor Belt is moved by hand rotating the Encoder Wheel? Go to Step 20. Go to Step 15. 15 Check Stacker Encoder Sensor Harness connections. Are P/J8328 and P/J8302B connected? Go to Step 17. Connect and go to Step 16. 16 Print a Test Print. Does the error still occur? Go to Step 17. Problem solved. 17 Check Stacker Encoder Sensor Harness continuity. 1. Disconnect P/J8328 on the harness, and P/J8302B on the Finisher Main PWB. 2. Check for continuity at the following: • P/J8328-3 <=> P/J8302B-12 • P/J8328-2 <=> P/J8302B-13 • P/J8328-1 <=> P/J8302B-14 Are these conductive? Go to Step 18. Repair the Stacker Encoder Sensor Harness. 18 Check for +5 V to Stacker Encoder Sensor. Is the voltage across J8302B-14 <=> J8302B-12 on the Finisher Main PWB? Go to Step 19. Replace the Finisher Main PWB. 19 Check Stacker Encoder Sensor signal. Does the voltage across P8302B-13 and P8302B-12 on the Finisher Main PWB change when the sensor is blocked? Replace the Finisher Main PWB. Replace Stacker Encoder Sensor. 20 Test the Elevator Motor. Run the Service Diagnostics Stacker Motor Up and Down tests alternately. Does the Elevator Motor operate? Replace the Finisher Main PWB. Go to Step 21. 21 Check the Elevator Motor connection. Is P/J8305 connected to the Finisher Main PWB? Go to Step 22. Connect and go to Step 22. 22 Print a Test Print. Does the error still occur? Go to Step 23. Problem solved. 23 Replace the Elevator Motor. Print a Test Print. Does the error still occur? Replace the Finisher Main PWB. Problem solved.

← Xem tất cả mã lỗi Xerox Phaser 5400

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie