Mã lỗi H5-81, H5-82 — Xerox Phaser 5400

Code: H5-81, H5-82

Description: Stacker Lower Tray Failure - H5-8n Eject Clamp Sensor The Eject Clamp Home Sensor does not change state within the time interval specified following the activation of the Eject Clamp. • Stacker Lower Tray Failure - H5-81 Eject Clamp SNR ON • Stacker Lower Tray Failure - H5-82 Eject Clamp SNR OFF
Causes: • Eject Clamp Home Sensor • Eject Clamp Sensor Harness • Finisher Main PWB • Eject Clamp Motor • Eject Clamp Motor Harness
Remedy: 1 Check the Eject Clamp operation. Rotate the Eject Clamp Motor. Does the Eject Clamp move smoothly? Go to Step 2. Correct the installation. 2 Test the Eject Clamp Home Sensor. Run the Service Diagnostics Eject Clamp Home Sensor test. Does the sensor change state? Go to Step 8. Go to Step 3. 3 Check Eject Clamp Sensor Harness connection. Are P/J8324 and P/J8302B connected? Go to Step 5. Connect and go to Step 4. 4 Print a Test Print. Does the error still occur? Go to Step 5. Problem solved. 5 Check Eject Clamp Sensor Harness continuity. 1. Disconnect P/J8324 and P/J8302B. 2. Check for continuity at the following: • P/J8324-3 <=> P/J8302B-6 • P/J8324-2 <=> P/J8302B-7 • P/J8324-1 <=> P/J8302B-8 Are these conductive? Go to Step 6. Repair the Eject Clamp Sensor Harness. 6 Check for +5 V to the Eject Clamp Home Sensor. Is there +5 V across J8302B-8 <=> J8302B- 6 on the Finisher Main PWB? Go to Step 7. Replace the Finisher Main PWB. 7 Check the Eject Clamp Home Sensor signal. Does the voltage across P8302B-7 <=> P8302B-6 on the Finisher Main PWB change when the sensor is blocked? Replace the Finisher Main PWB. Replace the Eject Clamp Home Sensor. 8 Test the Eject Clamp Motor. Run the Service Diagnostics Up and Down Eject Clamp Motor tests. Does the Eject Clamp Motor rotate normally? Replace the Finisher Main PWB. Go to Step 9. 9 Check Eject Clamp Motor Harness connections. Are P/J8339 and P/J8304 connected? Go to Step 11. Connect and go to Step 10. 10 Print a Test Print. Does the error still occur? Go to Step 11. Problem solved. 11 Check Eject Clamp Motor Harness continuity. 1. Disconnect P/J8339 and P/J8304. 2. Check for continuity at the following: • P/J8339-1 <=> P/J8304-33 • P/J8339-2 <=> P/J8304-31 Are these conductive? Go to Step 12. Repair the Eject Clamp Motor Harness. 12 Check Eject Clamp Motor voltage. Is there +24 V across P/J8304-31 and -33 <=> P/J8302A-1? Go to Step 13. Replace the Finisher Main PWB. 13 Replace the Eject Clamp Motor. Print a Test Print. Does the error still occur? Replace the Finisher Main PWB. Problem solved.

← Xem tất cả mã lỗi Xerox Phaser 5400

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie