Code: U4-2 ... U4-5
Description: Fuser Failure - U4-n Over Heat / Thermistor. • Fuser Failure - U4-2 Over Heat Temp • Fuser Failure - U4-3 FS1 Thermistor • Fuser Failure - U4-4 FS2 Thermistor • Fuser Failure - U4-5 Pressure Roller Thermistor
Causes: • Fuser • LVPS
Remedy: 1 Check the Fuser installation. Is the Fuser installed properly? Go to Step 2. Correct the installation. 2 For FS1 Thermistor Only. Is the resistance across P/J131-1 and P/ J131-2 more than or equal to 3 k-ohm? Go to Step 3. Replace the Fuser. 3 For FS2 Thermistor Only. Is the resistance between P/J132-1 and P/ J132-2 greater than or equal to 3 k-ohm? Go to Step 4. Replace the Fuser. 4 For Pressure Roller Thermistor Only. Is the resistance across P/J133-1 and P/ J133-2 greater than or equal to 3 k-ohm? Go to Step 5. Replace the Fuser. 5 Check the Fuser connection. Is P/J6 connected? Go to Step 6. Connect P/J6. 6 Check continuity between the Fuser and LVPS. Is there continuity on each wire between P/ J600 <=> P/J6? Go to Step 7. Repair the wiring. 7 Check power to the Fuser. Is there +XX V across P/JXXX (+) <=> ground? Replace the Fuser. Replace the LVPS.