Code: U4-7
Description: Fuser Failure - U4-7 Cold Sagging The Fuser temperature regulation failed. NOTE: Following display of this error, leave power applied for 7 minutes, then cycle printer power. If the error reoccurs, proceed with troubleshooting procedure.
Causes: • Fuser • LVPS • Engine Control Board
Remedy: 1 Check the Fuser for a paper jam. Open Door A. Is there a paper jam in the Fuser? Go to Step 2. Remove the paper. 2 Check the Fuser installation. Open Door A. Is the Fuser installed correctly? Go to Step 3. Install the Fuser correctly. 3 Test the Fuser Exit Sensor operation. 1. Open Door A. 2. Run the Service Diagnostics Fuser Exit Sensor test. Does sensor state change each time the Fuser is installed or removed? Go to Step 5. Go to Step 4. 4 Check the resistance of the Fuser. Is there an open circuit in the Center Thermistor between J131-1 and J131-2? Is the resistance of the Rear STS across J131-1 and J131-2 equal or greater than 3 kohm? Go to Step 7. Replace the Fuser. 5 Check the Pressure Roller Thermistor resistance. Is there an open circuit in the Pressure Roller Thermistor between J133-1 and J133- 2? Is the resistance of the Pressure Roller Thermistor across J133-1 and J133-2 more than or equal to 3 k-ohm? Go to Step 6. Replace the Fuser. 6 Check the Fuser for connection. Is LVPS P/J6 connected? Go to Step 7. Connect P/J6. 7 Check the Fuser connections. Are P/J410, P/J607, P/J600, P131 and P133 connected? Replace Engine Control Board. Connect P/J410, P/J607, P/J600, P131 and P133.