Mã lỗi H5-12 — Xerox Phaser 5500

Code: H5-12

Description: Stacker Lower Tray Failure - H5-12 Low Tray Upper Limit The Stacker Lower Tray rose beyond the upper limit position.
Causes: • Lower Tray No Paper Sensor • Lower Tray Upper Limit Sensor • Upper Limit Actuator • Finisher Main PWB • Main Sensor Harness • Elevator Harness • Engine Control Board
Remedy: 1 Check the Stacker Lower Tray vertical transport and belts for obstacles and deformation. Are there obstacles or belt wear in the vertical transport mechanism? Remove any obstacles. Go to Step 2. 2 Check the Actuator installation. Does the Actuator enter the Upper Limit sensor sensing area? Go to Step 3. Replace the Actuator. 3 Test the Lower Tray No Paper Sensor. Run the Service Diagnostics Lower Tray No Paper Sensor test. Does the sensor state change when the sensor is blocked? Go to Step 9. Go to Step 4. 4 Check the Lower Tray No Paper Sensor Harness connection. Are P/J8326 and P/J8302B connected? Go to Step 6. Connect and go to Step 5. 5 Print a Test Print. Does the error still occur? Go to Step 6. Problem solved. 6 Check Main Sensor Harness continuity. 1. Disconnect P/J8326 on the Main Sensor Harness, and P/J8302B on the Finisher Main PWB. 2. Check for continuity at the following: • P/J8326-3 <=> P/J8302B-15 • P/J8326-2 <=> P/J8302B-16 • P/J8326-1 <=>P/J8302B-17 Are these conductive? Go to Step 7. Repair the Main Sensor Harness. 7 Check for +5 V to the Lower Tray No Paper Sensor. Is there +5 V across J8302B-17 <=> J8302B-15 on the Finisher Main PWB? Go to Step 8. Replace the Finisher Main PWB. 8 Check the Lower Tray No Paper Sensor. Does the voltage across P8302B-16 <=> P8302B-15 on the Finisher Main PWB change when the sensor is blocked? Replace the Finisher Main PWB. Replace the Lower Tray No Paper Sensor. 9 Test the Lower Tray Upper Limit Sensor. Run the Service Diagnostics Lower Tray Upper Limit Sensor test. Does the sensor state change when the sensor is blocked? Go to Step 15. Go to Step 10. 10 Check Lower Tray Upper Limit Sensor Harness connection. Are P/J8327 and P/J8302B connected? Go to Step 12. Connect and go to Step 11. 11 Print a Test Print. Does the error still occur? Go to Step 12. Problem solved. 12 Check Lower Tray Upper Limit Sensor Sensor Harness continuity. 1. Disconnect P/J8327 on the harness, and P/J8302B on the Finisher Main PWB. 2. Check for continuity at the following: • P/J8327-3 <=> P/J8302B-18 • P/J8327-2 <=> P/J8302B-19 • P/J8327-1 <=> P/J8302B-20 Are these conductive? Go to Step 13. Repair the Lower Tray Upper Limit Sensor Harness. 13 Check for +5 V to the Lower Tray Upper Limit Sensor. Is there +5 V across J8302B-20 <=> J8302B-18 on the Finisher Main PWB? Go to Step 14. Replace the Finisher Main PWB. 14 Check Lower Tray Upper Limit Sensor signal. Does the voltage across P8302B-19 <=> P8302B-18 on the Finisher Main PWB change when the sensor is blocked? Replace the Finisher Main PWB. Replace the Lower Tray Upper Limit Sensor. 15 Test the Elevator Motor. Run the Service Diagnostics Stacker Motor Up and Down tests alternately. Does the Elevator Motor operate? Replace the Finisher Main PWB. Go to Step 16. 16 Check the Elevator Motor connection. Is P/J8305 connected to the Finisher Main PWB? Go to Step 18. Connect and go to Step 17. 17 Print a Test Print. Does the error still occur? Go to Step 18. Problem solved. 18 Replace the Elevator Motor. Print a Test Print. Does the error still occur? Go to Step 19. Problem solved. 19 Replace the Finisher Main PWB. Does the error still occur? Replace the Engine Control Board. Problem solved.

← Xem tất cả mã lỗi Xerox Phaser 5500

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie