Code: U3-5
Description: Laser Motor Failure - U3-5 Polygon Motor Rotation The Scanner Motor, located in the Laser Assembly, failed.
Causes: • Drum Cartridge • Laser Assembly • Engine Control Board
Remedy: 1 Check the Drum Cartridge installation. Is the Drum Cartridge installed properly? Go to Step 2. Correct the installation. 2 Test the Scanner Motor. Run the Service Diagnostics Laser Scan Motor test. Does the motor run? Replace Laser Assembly or Engine Control Board. Go to Step 4. 3 Check the Laser connection. Are P/J140 and P/J406 connected? Go to Step 4. Connect the Laser Assembly. 4 Check the Laser connections. Are P/J130, P/J620 and P/J406 connected? Go to Step 5. Connect P/J130, P/J620 and P/ J406. 5 Check continuity between the Laser and the Engine Control Board. Is there continuity on each wire between P/ J140 <=> P/J406? Go to Step 6. Repair the wiring. 6 Check continuity between the Laser and the Engine Control Board. Is there continuity on each wire between P/ J130 <=> P/J406? Go to Step 7. Repair the wiring. 7 Check for +5 V to the Laser. Is there +5 V across P/J140-8 (+) <=> ground? Go to Step 8. Replace the Engine Control Board. 8 Check for +24 V to the Laser. Is there +24 V across P/J130-5 (+) <=> ground? Replace the Laser Assembly. Replace the Engine Control Board.