Code: 042-372
Description: Deve Mode Change Failure
Causes: • Feed Solenoid, PL6.1.10 • Switching Sensor • HARNESS ASSY RKN SNS PL2.2.25/26 • Developer Drive Assembly, PL6.1.6 • MCU Board, PL7.2.2
Remedy: 1 Check the P/J10 connector on the MCU Board. Is P/J10 connected correctly? Go to step 2. Reseat the connector. Go to step 2. 2 Does the error persist when the power is turned on? Go to step 3. Complete. 3 Test the Feed Solenoid. Enter diagnostic mode and select Engine Diag > Motor Test > K Mode Solenoid (see “Using Phaser 6010N Service Diagnostics” on page 4-6). You can also use the CE Diag Tool to perform this test. Does the Feed Solenoid function normally? Go to step 4. Replace the Feed Solenoid. 4 Check the connections between the MCU Board P/J12 and the Feed Sensor P/J122. Are the connections secure? Go to step 5. Reseat the connector. Go to step 5. 5 Does the error persist when the power is turned on? Go to step 6. Complete. 6 Disconnect the MCU Board P/J21and the Registration Sensor P/J120. Check the harness assy rkn sns for continuity. Is the harness damaged? Repair the harness. Go to step 7. 7 Disconnect P/J12 on the MCU Board. Is the voltage across ground to P/J12-7 approximately +3.3 VDC? Replace the Developer Drive Assembly. Replace the MCU Board.