Code: 093-423 ... 093-426
Description: X CRU Near Life A Low Toner Cartridge (C, M, Y, or K) state was detected. • 093-423: X CRU Near Life • 093-424: X CRU Near Life • 093-425: X CRU Near Life • 093-426: X CRU Near Life
Causes: • Harn assy dckr, PL4.1.2 • MCU Board, PL7.2.2
Remedy: • Replace the indicated Toner Cartridge. • Cycle printer power. • If the problem persists, follow this procedure.
1 Reseat the Toner Cartridge. Does the error persist? Go to step 2. Complete. 2 Check P/J13 on the MCU Board. Is the connector secure? Go to step 4. Reconnect P/J13, then go to step 3. 3 Does the error persist? Go to step 4. Complete. 4 Replace the MCU Board. Does the error persist? Contact your designated field support for assistance. Complete.
1 Reseat the Toner Cartridge. Does the error persist? Go to step 2. Complete. 2 Check P/J13 on the MCU Board. Is the connector secure? Go to step 4. Reconnect P/J13, then go to step 3. 3 Does the error persist? Go to step 4. Complete. 4 Replace the MCU Board. Does the error persist? Contact your designated field support for assistance. Complete.