Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 077-304 — Xerox Phaser 6022

Code: 077-304

Description: Rear Cover Open The rear cover is open.
Causes: • Rear Door, PL1.1.6 • Rear I/L Switch Assembly, PL1.1.12 • LVPS, PL7.2.1 • MCU Board, PL7.2.2
Remedy: 1. Visually inspect the Rear Door for damage. Is the Rear Door damaged? Replace the Rear Door for Phaser 6020, or for Phaser 6022, or for WorkCenter 6025 MFP, or for WorkCenter 6027 MFP. Go step 2. 2. Enter diagnostic mode and run the Cover Open Sensor test (see. Does the number on the display increase by 1 each time the door is opened?. Go to step 4. Go to step 3. 3. Replace the Rear I/L Switch Assembly for Phaser 6020, or for 6022, or for WorkCenter 6025 MFP, or for WorkCenter 6027 MFP. Does the error persist? Go to step 4. Complete. 4. Replace the LVPS. Does the error still occur when printing? 1. SaveNVM to ESS 2. Replace the MCU Board. 3. LoadNVM from ESS Complete.