Code: 17
Description: Toner Carousel Failure
Causes: Toner Carousel Motor (M2) Toner Carousel Positioning Sensor (PC3) PWB-A (Engine Control Board)
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 PC3 sensor check. PWB-A PJ5A-11 (ON) 4-C 5 M2 operation check. PWB-A PJ5A-1¡«4 (Pulse Output) 4-B 6 Change PWB-A.