Code: 010-351
Description: Replace Fuser / Fuser Life The Fuser has reached end of life.
Causes: Fuser (PL6.1.1) MCU Board (PL8.2.13)
Remedy: 1 Check the life counter value of the Fuser Does the life counter value show the near of the end? Replace the Fuser. After replacing the Fuser, be sure to reset the life counter value. Go to step 2. 2 Check after reseating the Fuser Reseat the Fuser. Warning: Start the operation after the Fuser has cooled down. Does the error still occur when the power is turned OFF and ON? Go to step 3. Complete 3 Check after replacing the Fuser Replace the Fuser. Warning: Start the operation after the Fuser has cooled down. Does the error still occur when the power is turned OFF and ON? NOTE: After replacement, be sure to clear the life counter value. Replace the MCU Board. Complete