Code: 010-397
Description: Fuser Error
Causes: Fuser (PL6.1.1) LVPS Board (PL8.2.1) MCU Board (PL8.2.13)
Remedy: 1 Does the error still occur when the power is turned OFF and ON? Go to step 2. Complete 2 Check after reseating the Fuser Reseat the Fuser. Warning: Start the operation after the Fuser has cooled down. Does the error still occur when the power is turned OFF and ON? Go to step 3. Complete 3 Check the connectors for connection Remove the Fuser. Warning: Start the operation after the Fuser has cooled down. Check the connections between the MCU Board (P/J17) and Fuser (P/ J171). Check the connections between the Fuser (P/J171) and LVPS Board (P/ J47). Check the connections between the LVPS Board (P/J501 and P/J502) and MCU Board (P/J14 and P/J15). Are these connectors connected correctly? Go to step 5. Reconnect the connector(s) P/ J17, P/J47, P/ J171, P/J501, P/ J502, P/J14 and/or P/J15 correctly, then go to step 4." 4 Does the error still occur when the power is turned OFF and ON? Go to step 5. Complete 5 Check the Fuser Harness Assy for continuity Disconnect J17 from the MCU Board. Disconnect J47 from the LVPS Board. Is each cable of J17 and J47 <=> P171 continuous? NOTE: P171 is attached to the frame. Go to step 6. Replace the Fuser Harness Assy. 6 Check the LVPS Harness Assy for continuity Disconnect J14 from the MCU Board. Disconnect J501 from the LVPS Board. Is each cable of J14 <=> J501 continuous? Go to step 7. Replace the LVPS Harness Assy. 7 Check after replacing the Fuser Replace the Fuser. Warning: Start the operation after the Fuser has cooled down. Does the error still occur when the power is turned OFF and ON? NOTE: After replacement, be sure to clear the life counter value. Go to step 8. Complete 8 Check after replacing the LVPS Board Replace the LVPS Board. Complete