Mã lỗi 042-326 — Xerox Phaser 6125

Code: 042-326

Description: Sub Motor Error The Sub Motor has failed.
Causes: • MCU Board, PL8.2.13 • Sub Drive Assembly, PL7.1.1
Remedy: 1 Check the Imaging Unit and Fuser for correct installation. Are the Imaging Unit and Fuser correctly installed? Go to step 3. Reseat the Imaging Unit and Fuser. Go to step 2. 2 Does the error still occur? Go to step 3. Complete. 3 1. Close the Front Cover. 2. Perform the Sub Motor test: Service Mode > Engine Diag > Motor Test > Sub Motor FULL2. Does the Sub Motor operate properly? Replace the MCU Board. Go to step 4. 4 Check the wiring harness connectors P/J22 and P/J221 between the MCU Board and the Sub Drive Assembly. Are the connectors securely connected? Go to step 6. Reconnect the connectors. Go to step 5. 5 Does the error still occur? Go to step 6. Complete. 6 Check the Sub Drive Assembly for correct installation. Is it correctly installed? Go to step 8. Reseat the Main Drive. Go to step 7. 7 Does the error still occur? Go to step 8. Complete. 8 Check power to the Sub Drive Assembly. 1. Disconnect P/J22 from the MCU Board. 2. Are there +24 V across J22-2/J22-4 <=> ground when the Interlock Switch is activated? Replace the Sub Drive Assembly. Replace the MCU Board.