Code: 091-916
Description: Replace Imaging Unit/PHD CRUM Error
Causes: • MCU Board, PL8.2.13 • Imaging Unit, PL4.1.21
Remedy: 1 Check the Imaging Unit type Is the correct Imaging Unit installed? Go to step 3. Replace with the correct Imaging Unit, then go to step 2. 2 Does the error still occur when the power is turned OFF and ON? Go to step 3. Complete 3 Reseat the Imaging Unit. Does the error still occur when the power is turned OFF and ON? Go to step 4. Complete 4 Check the connectors to the MCU Board and Imaging Unit. Are P/J42 and P/J422 connected correctly? Go to step 6. Reconnect the connector(s) P/ J42 and/or P/ J422 securely, then go to step 5. 5 Does the error still occur when the power is turned OFF and ON? Go to step 6. Complete 6 Replace the Imaging Unit. Does the error still occur when the power is turned OFF and ON? Replace the MCU Board. Complete