Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi -09 — Xerox Phaser 6128 MFP

Code: -09

Description: Front Cover Open Close Front Cover The Interlock Switch indicates the Front Cover is open. The following troubleshooting procedure applies to this error.
Causes: • Front Cover, PL1.1.8 • Interlock Harness, PL10.6.4 • LVPS, PL10.6.16 • MCU Board, PL10.7.7 • LVPS Main Harness, PL10.8.14
Remedy: 1 Check Interlock Switch operation. Run the Interlock Switch test (DI-07). Does the Switch operate? Replace the MCU Board. Go to step 2. 2 Check the Interlock Harness connections P/J14 and P/J501. Are the connections secure? Go to step 3. Secure the connections. 3 Check continuity of the LVPS Main Harness. Disconnect P/J14 from the MCU Board and P/J501 from the LVPS. Is the harness damaged? Repair the harness. Go to step 4. 4 Check for +24 V on P44 of the LVPS. Is there +24 V between P44-1 <=> ground? Go to step 5. Replace the LVPS. 5 Check the Interlock Switch signal. Does the voltage between P44-3 <=> ground change when the switch is closed? Replace the LVPS. Replace the Interlock Harness. 6 Replace the Interlock Switch Harness. Does the error persist? Replace the MCU Board. Complete.