Mã lỗi 024-371 — Xerox Phaser 6128 MFP

Code: 024-371

Description: MCU Communication Error Communication has failed between the Engine and the Controller. The following troubleshooting procedure applies to this error.
Causes: • Image Processor Board, PL10.6.6 • MCU Board, PL10.7.7 • ESS Harness, PL10.8.1
Remedy: 1 Reseat connections to the I/P and MCU Boards then cycle system power; Does the error persist? Go to step 2. Complete. 2 Check P/J901 and P/J10 connections between the I/P and MCU Boards. Are the connections secure? Go to step 3. Reseat the connectors. 3 Disconnet P/J901 and P/J10 and check the harness continuity. Is the harness damaged? Repair the harness. Go to step 4. 4 Replace the MCU Board. Does the error persist? Replace the I/P Board. Complete.