Code: 042-325
Description: Main Motor Error The Main Motor has failed. The following troubleshooting procedure applies to this error.
Causes: • Main Drive, PL7.1.2 • MCU Board, PL10.7.7 • Main Motor Harness, PL10.8.7
Remedy: 1 Check the Transfer Belt, Fuser, and Imaging Unit for correct installation. Are the parts correctly installed? Go to step 3. Correct any problems found. 2 Does the error persist when the power is turned On? Go to step 3. Complete. 3 Run the Main Motor test (DO-00) on. Does the motor rotate? Go to step 4. Go to step 5. 4 Check connectors P/J21 and P/J211 between the MCU Board and Main Motor Assembly. Are the connectors secure? Go to step 5. Reconnect the connectors. 5 Check the Main Drive harness continuity. Disconnect P/J21 from the MCU Board and P/J211 from the Main Drive to check continuity. Is the harness damaged? Repair or replace the harness (PL10.8.7). Go to step 6. 6 Check the Main Drive Assembly for correct installation. Is the Main Drive Assembly installed correctly? Go to step 7. Reseat the Main Drive Assembly. 7 Check for +24 V at J21 on the MCU Board. Is +24 V available at J21-2 and J21- 4 when the Interlock Switch is closed? Replace the Main Drive Assembly. Replace the MCU Board.