Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 042-326 — Xerox Phaser 6128 MFP

Code: 042-326

Description: Sub Motor Error The Sub Motor failed. This troubleshooting procedure applies to this error.
Causes: • Sub Drive Assembly, PL7.1.1 • MCU Board, PL10.7.7 • Sub Motor Harness, PL10.8.8
Remedy: 1 Check the Transfer Belt, Fuser, and Imaging Unit for correct installation. Are the parts correctly installed? Go to step 3. Correct any problems found. 2 Does the error persist when the power is turned On? Go to step 3. Complete. 3 Run the Sub Motor test (DO-05) on. Does the motor rotate? Go to step 4. Go to step 15. 4 Check connectors P/J22 and P/J221 between the MCU Board and Sub Drive Assembly. Are the connectors secure? Go to step 5. Reconnect the connectors. 5 Check the Sub Drive harness continuity. Disconnect P/J22 from the MCU Board and P/J221 from the Sub Drive to check continuity. Is the harness damaged? Repair or replace the harness (PL10.8.8). Go to step 6. 6 Check the Sub Drive Assembly for correct installation. Is the Sub Drive Assembly installed correctly? Go to step 7. Reseat the Sub Drive Assembly. 7 Check for +24 V at J22 on the MCU Board. Is +24 V available at J22-2 and J22- 4 when the Interlock Switch is closed? Replace the Sub Drive Assembly. Replace the MCU Board.

← Xem tất cả mã lỗi Xerox Phaser 6128 MFP