Code: 042-358
Description: Fan Motor Error The Fan has failed. The following troubleshooting procedure applies to this error.
Causes: • Fan, PL10.6.7 • LVPS, PL106.16 • MCU Board, PL10.7.7 • LVPS Harness, PL10.8.3
Remedy: 1 Run the Fan test (DO-1e or DO-1f): Does the Fan rotate? Replace the MCU Board. Go to Step 2. 2 Check P/J503 on the LVPS. Is the connection secure? Go to step 3. Connect the Fan. 3 Check the Main LVPS harness continuity. Disconnect P/J501from the LVPS and P/J14 from the MCU Board. Is the harness damaged? Repair or replace the LVPS Harness (PL10.8.14). Go to step 4. 4 Check for +24 V at J503 on the MCU Board. Is +24 V available at J503-1 <=> ground when the Interlock Switch is closed? Replace the Fan. Go to step 5. 5 Replace the LVPS. Does the error persist? Replace the MCU Board. Complete.