Code: 042-326
Description: Sub Motor Error The Sub Motor has failed. The following troubleshooting procedure applies to this error.
Causes: • Print Cartridge (C/M/Y/K), PL5.1-17-20 • Main Drive, PL8.1.2 • MCU Board, PL9.2.13 • Right Side Harness, PL10.1.12
Remedy: 1 1. Check the Print Cartridges for correct installation. 2. Are the Print Cartridges correctly installed? Go to step 3. Reseat the Print Cartridges. Go to step 2. 2 Does the error still occur when the printer is turned On? Go to step 3. Complete. 3 1. Check the wiring harness connectors P/J22 and P/J221 between the MCU Board and the Main Drive. 2. Are the connectors securely connected? Go to step 4. Reconnect the connectors. Go to step 4. 4 1. Perform the Sub Motor test: Service Mode > Printer Diag > Engine Diag > Motor Test > Sub Motor. During the test, close the Front Cover. 2. Does the Motor operate properly? Replace the MCU Board. Go to step 5. 5 1. Check the Main Drive for correct installation. 2. Is the Main Drive correctly installed? Go to step 6. Reseat the Main Drive. Go to step 6. 6 Does the error still occur when the printer is turned On? Go to step 7. Complete. 7 Check the Right Side Harness for continuity. 1. Disconnect P/J22 from the MCU Board. 2. Disconnect P/J221 from the Drive Assembly. 3. Check continuity between P/J22 <=> P/J221. Go to step 8. Replace the Right Side Harness. 8 Check the Main Drive signal. 1. Disconnect P/J22 from the MCU Board. 2. Is there +24 V across ground <=> J22-A2/J22-A4 pin when the Interlock Switch is activated? Replace the Main Drive. Replace the MCU Board.