Code: 093-925
Description: Print Cartridge CRUM Error (Yellow/Magenta/Cyan/Black) The Print Cartridge CRUM communication is detected. The following troubleshooting procedure applies to these errors. • Chain Link 093-925: Black CRUM Error
Causes: • Print Cartridge (Y/M/C/K), PL5.1.17-20 • CRUM Connector, PL5.2.1 • MCU Board, PL9.2.13 • CRUM Harness, PL10.1.9
Remedy: 1 1. Check the Print Cartridge(s) for correct installation. 2. Is the Print Cartridge(s) correctly installed? Go to step 3. Reseat the Print Cartridge(s). Go to step 2. 2 Does the error still occur when the printer is turned On? Go to step 4. Complete. 3 Is the Print Cartridge a Xerox Print Cartridge? Go to step 5. Install a Xerox Print Cartridge. 4 1. Check the CRUM Connector for correct installation. 2. Is the connector securely connected? Go to step 5. Reseat the CRUM Connector. Go to step 5. 5 1. Check the wiring harness connector(s) between the CRUM Connector and the MCU Board. • Yellow: P/J31 and P/J311 • Magenta: P/J31 and P/J312 • Cyan: P/J31 and P/J313 • Black: P/J31 and P/J314 2. Is the connector(s) securely connected? Go to step 6. Reconnect the connector(s). Go to step 6. 6 Check the CRUM Harness for continuity. 1. Disconnect the wiring harnesses from the Connector CRUM and MCU Board. • Yellow: P/J31 and P/J311 • Magenta: P/J31 and P/J312 • Cyan: P/J31 and P/J313 • Black: P/J31 and P/J314 2. Check continuity between P/J connectors: • Yellow: P/J31 <=> P/J311 • Magenta: P/J31 <=> P/J312 • Cyan: P/J31 <=> P/J313 • Black: P/J31 <=> P/J314 Go to step 7. Replace the CRUM Harness. 7 Check the CRUM Connector for damages. Is the CRUM Connector damaged? Replace the CRUM Connector. Go to step 8. 8 1. Replace the CRUM Connector. 2. Does the error still occur when the printer is turned On? Go to step 9. Complete. 9 1. Replace the Print Cartridge. 2. Does the error still occur? Replace the MCU Board. Complete.