Mã lỗi 042-326 — Xerox Phaser 6180 MFP

Code: 042-326

Description: Sub Motor Error The Sub Motor has failed. The following troubleshooting procedure applies to this error.
Causes: • Print Cartridge (C/M/Y/K), PL5.1-17-20 • Main Drive, PL8.1.2 • MCU Board, PL9.2.13 • Right Side Harness, PL10.1.12
Remedy: 1 1. Check the Print Cartridges for correct installation. 2. Are the Print Cartridges correctly installed? Go to step 3. Reseat the Print Cartridges. Go to step 2. 2 Does the error still occur when the printer is turned On? Go to step 3. Complete. 3 1. Check the wiring harness connectors P/J22 and P/J221 between the MCU Board and the Main Drive. 2. Are the connectors securely connected? Go to step 4. Reconnect the connectors. Go to step 4. 4 1. Perform the Sub Motor test: Service Mode > Printer Diag > Engine Diag > Motor Test > Sub Motor. During the test, close the Front Cover. 2. Does the Motor operate properly? Replace the MCU Board. Go to step 5. 5 1. Check the Main Drive for correct installation. 2. Is the Main Drive correctly installed? Go to step 6. Reseat the Main Drive. Go to step 6. 6 Does the error still occur when the printer is turned On? Go to step 7. Complete. 7 Check the Right Side Harness for continuity. 1. Disconnect P/J22 from the MCU Board. 2. Disconnect P/J221 from the Drive Assembly. 3. Check continuity between P/J22 <=> P/J221. Go to step 8. Replace the Right Side Harness. 8 Check the Main Drive signal. 1. Disconnect P/J22 from the MCU Board. 2. Is there +24 V across ground <=> J22-A2/J22-A4 pin when the Interlock Switch is activated? Replace the Main Drive. Replace the MCU Board.

← Xem tất cả mã lỗi Xerox Phaser 6180 MFP

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie