Mã lỗi 092-661 — Xerox Phaser 6180 MFP

Code: 092-661

Description: Environmental (Humidity/Temperature) Sensor Error The Environmental Sensor has detected temperature error. The following troubleshooting procedure applies to this error.
Causes: • Humidity/Temperature Sensor PL9.2.11 • MCU Board, PL9.2.13 • Humidity Harness, PL10.1.15
Remedy: 1 1. Check the Humidity/Temperature Sensor for correct installation. 2. Is the Humidity/Temperature Sensor correctly installed? Go to step 2. Reseat the Humidity/ Temperature Sensor. Go to step 2. 2 Does the error still occur when the printer is turned On? Go to step 3. Complete. 3 1. Check the wiring harness connectors P/J26 and P/J261 between the MCU Board and the Humidity/Temperature Sensor. 2. Are the connectors securely connected? Go to step 4. Reconnect the connectors. 4 Check the Humidity Harness for continuity. 1. Disconnect P/J26 from the MCU Board. 2. Disconnect P/J261 from the Humidity/Temperature Sensor. 3. Check continuity between P/J26 <=> P/J261. Go to step 5. Replace the Humidity Harness. 5 Check the Humidity/Temperature Sensor signal. 1. Disconnect P/J26 from the MCU Board. 2. Is there +5 V across ground <=> J26-4 pin on the MCU Board? Replace the Humidity/ Temperature Sensor. Replace the MCU Board.