Code: 093-320
Description: Deve Motor Error The Deve Motor has failed. The following troubleshooting procedure applies to this error.
Causes: • Feeder Kit, PL3.2.1 • Main Drive, PL8.1.2 • MCU Board, PL9.2.13 • Right Side Harness, PL10.1.12
Remedy: 1 1. Check the Print Cartridges for correct installation. 2. Are the Print Cartridges correctly installed? Go to step 3. Reseat the Print Cartridges. Go to step 2. 2 Does the error still occur when the printer is turned On? Go to step 3. Complete. 3 1. Check the wiring harness connectors P/J22 and P/J222 between the MCU Board and the Main Drive. 2. Are the connectors securely connected? Go to step 4. Reconnect the connectors. Go to step 4. 4 1. Perform the Deve Motor test: Service Mode > Printer Diag > Engine Diag > Motor Test > Deve Motor. Close the Front Door while running the test. 2. Does the Motor operate properly? Replace the MCU Board. Go to step 5. 5 1. Check the Main Drive Assembly for correct installation. 2. Is the Main Drive Assembly correctly installed? Go to step 6. Reseat the Main Drive Assembly. 6 Does the error still occur when the printer is turned On? Go to step 7. Complete. 7 1. Check the wiring harness connectors P/J22 and P/J222 between the MCU Board and the Main Drive Assembly. 2. Are the connectors securely connected? Go to step 8. Reconnect the connectors. 8 Check the Right Side Harness for continuity. 1. Disconnect P/J22 from the MCU Board. 2. Disconnect P/J222 from the Main Drive Assembly. 3. Check continuity between P/J22 <=> P/J252. Go to step 9. Replace the Right Side Harness. 9 Check the Main Drive Assembly signal. 1. Disconnect P/J22 from the MCU Board. 2. Is there +24 V across ground <=> J22-B2/J22-B4 pin when the Interlock Switch is activated? Replace the Main Drive Assembly. Replace the MCU Board.