Code: 105
Description: Main Motor Failure The Main Motor rotation signal indicates that the motor is no longer operational.
Causes: • Main Drive Assembly, PL8.1.2 • Engine Control Board, PL9.1.16 • FAN/PHD/MOT Harness, PL10.1.9
Remedy: 1 Check the Main Drive Assembly for damage. Are any parts damaged? Replace the Main Drive Assembly. Go to Step 2. 2 Check the Main Motor connection. Is P/J481 connected to the harness? Go to Step 3. Reconnect the Main Motor. 3 Test the Main Motor. 1. Close the Interlock Switch while testing. 2. Run the Service Diagnostics Main Motor test. Does the motor operate? Go to Step 5. Go to Step 4. 4 Check for +24 V to the Main Motor. Is there +24 V across P/J481-10 <=> P/J 481-8? Go to Step 6. Go to Step 5. 5 Test the Interlock Switch. Run the Service Diagnostics Interlock Switch test. Does the switch function correctly? Go to Step 6. Replace the Interlock Switch. 6 Check all pins on the FAN/PHD/MOT Harness, PL10.1.9 for continuity. 1. Disconnect P/J48 and P/J481. 2. Check continuity between J48 <=> J481. Replace the Engine Control Board. Replace the FAN/PHD/MOT Harness.