Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 207 — Xerox Phaser 6350

Code: 207

Description: Replace Fuser The Fuser Life counter indicates that the Fuser has reached its end of life. Fuser replacement is necessary to avoid print quality problems.
Causes: • Fuser, PL5.1.1 • FSR/ADC Harness PL5.2.28 • EEPROM Board, PL 9.1.12 • EEPROM Harness, PL10.1.8
Remedy: 1 Check the Fuser connector for damage. Re-establish proper connection or replace the parts concerned. Power cycle the printer. Go to Step 2. 2 Replace the Fuser. Does the error persist? Go to Step 3. Complete 3 Replace the EEPROM Board Does the error persist? Go to Step 4. Complete 4 Check all pins on the EEPROM Harness PL10.1.8 for continuity. 1. Disconnect P/J191 and P/J144. 2. Check continuity between J191<=>J144. Go to Step 5. Replace the EEPROM Harness. 5 Check all pins on the FSR/ADC Harness PL5.2.28 for continuity. 1. Disconnect P/J36 and J361. 2. Check continuity between J36 <=> J361. Replace the Engine Control Board. Replace the FSR/ADC Harness.