Code: 104
Description: Developer Motor Failure The Developer Motor rotation signal indicates that the motor is no longer operational.
Causes: • Developer Drive Assembly, PL8.1.1 • Engine Control Board, PL9.1.16 • Interlock Switch, PL9.1.11 • FAN/PHD/MOT Harness, PL10.1.9
Remedy: 1 Check the Developer Drive Assembly for damage. Are any parts of the Developer Drive Assembly damaged or excessively worn? Replace the Developer Drive Assy. Go to Step 2. 2 Check the Developer Motor connection. Is P/J491 connected to the harness? Go to Step 3. Reconnect the Developer Motor. 3 Test the Developer Motor. 1. Close the Interlock Switch while testing. 2. Run the Service Diagnostics Developer Motor test. Does the motor operate? Go to Step 5. Go to Step 4. 4 Check for +24 V to the Developer Motor. Is the +24 V across P/J491-1 <=> P/J 481-5? Go to Step 6. Go to Step 5. 5 Test the Interlock Switch. Run the Service Diagnostics Interlock Switch test. Does the switch function correctly? Go to Step 6. Replace the Interlock Switch. 6 Check all pins on the FAN/PHD/MOT Harness PL10.1.9 for continuity. 1. Disconnect P/J48 and P/J491. 2. Check continuity between J48 <=> J491. Replace the Engine Control Board. Replace the FAN/PHD/MOT Harness.