Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 13 ... 16 — Xerox Phaser 6360

Code: 13 ... 16

Description: Density Sensor Failure An error was detected in the CTD (ADC) sensor. Code 13: Density Sensor Failure. Code 14: Density Limit Over Output. Code 15: Density Limit. Code 16: This is the generic fault used by the engine if a lower level error cannot be reported to the controller.
Causes: • Transfer Roller, PL5.1.4 • FSR/ADC Harness, PL5.2.28 • CTD(ADC) Sensor Holder, PL5.2.19
Remedy: 1 Check the following for evidence of fault or damage: • Transfer Roller, PL5.1.4 • CTD (ADC) Sensor Holder, PL5.2.19 Are any parts damaged? Replace any damaged parts. Go to Step 2. 2 Clean the CTD (ADC) Sensor. Does the error persist? Go to Step 3. Complete 3 Test the CTD (ADC) Sensor. Run the Service Diagnostics CTD (ADC) Sensor test. Does the sensor function correctly? Go to Step 4. Go to Step 5. 4 Replace the Transfer Roller. Does the error persist? Go to Step 5. Complete 5 Check all pins on the FSR/ADC Harness PL5.2.28 for continuity. 1. Disconnect P/J36 and P/J136. 2. Check continuity between J36 <=> J136. Go to Step 6. Replace the FSR/ ADC Harness. 6 Check the CTD (ADC) Sensor signal. Disconnect P/J136. Is there 0 V across P136-4 <=> P136-1? Replace the CTD (ADC) Sensor Holder. Replace the Engine Control Board.