Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 041-340 — Xerox Phaser 6500

Code: 041-340

Description: IOT NVRAM Error
Causes: • Imaging Unit (PL4.1.21) • MCU Board (SFP PL8.2.13; MFP PL8.3.6) • EEPROM Board (SFP PL8.2.16; MFP PL8.3.4) • PHD XPRO Harness Assy (PL9.1.11)
Remedy: 1 Does the error still occur after cycling the power On and Off several times? Go to step 2. Complete.a 2 Reseat the Imaging Unit and four Toner Cartridges. Does the error still occur when the power is turned Off and On? Go to step 3. Complete.a 3 Reseat the MCU Board. Does the error still occur when the power is turned Off and On? Go to step 4. Complete.a 4 Check the connectors for connection. Check the connections between the PWBA EEPROM and MCU Board. Are P/J 144, and P/J 42 connected surely? Go to step 6. Reconnect the connector(s) P/ J42 and P/ J144 securely, then go to step 5. 5 Does the error still occur when the power is turned Off and On? Go to step 6. Complete. 6 Check the PHD XPRO Harness Assy for continuity. Disconnect J42 from the MCU Board. Disconnect J144 from the EEPROM Board. Is each cable of J42 <=> J144 continuous? Go to step 7. Replace the PHD XPRO Harness Assy 7 Check the power to the EEPROM Board. Disconnect J42 from the MCU Board. Is the voltage across P42-3 <=> ground on the MCU Board, about +3.3 VDC? Replace the EEPROM Board Go to step 8. 8 Replace the MCU Board. Does the error still occur when the power is turned Off and On? Go to “Electrical Noise” on page 4-79. Complete.

← Xem tất cả mã lỗi Xerox Phaser 6500

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie