Remedy: 1 Does the error still occur when the power is turned Off and On? Go to step 2. Complete. 2 Check the Fan for rotation. In the Printer Diagnostic tests, use Engine Diag > Motor Test > Fan HIGH. During this check, close the Front Cover. Does the Fan function normally? Replace the MCU Board. Go to step 3. 3 Check the connection between the Fan and the LVPS. Is P/J503 on the LVPS connected correctly? Go to step 5. Reconnect the connector P/J 503, then go to step 4. 4 Does the error still occur when the power is turned Off and On? Go to step 5. Complete. 5 Check the connections between the LVPS and MCU Board. Are P/J501 and P/J14 connected correctly? Go to step 7. Reconnect the connector(s) P/ J501 and P/ J14 correctly, then go to step 6. 6 Does the error still occur when the power is turned Off and On? Go to step 7. Complete. 7 Check the LVPS Main Harness Assy for continuity. Disconnect J501 from the LVPS. Disconnect J14 from the MCU Board. Is each wire of J501 <=> J14 continuous? Go to step 8. Replace the LVPS Main Harness Assy. 8 Check the power to the Fan. Disconnect J503 from the LVPS. Is the voltage across P503-1 <=> ground on the LVPS, about +24 VDC when the interlock switch (Interlock Harness Assy) is pushed? Replace the Fan. Go to step 9. 9 Replace the LVPS. Does the error still occur when the power is turned Off and On? Replace the MCU Board. Complete.