Remedy: 1 Does the error occur when the power is turned Off and On? Go to step 2. Complete. 2 Reseat the Imaging Unit. Does the error still occur when the power is turned Off and On? Go to step 3. Complete. 3 Check the Main Motor for rotation. In the Printer Diagnostic tests, use Engine Diag > Motor Test > Main Motor FULL1. Does the Main Motor function normally? Replace the MCU Board. Go to step 4. 4 Check the connections between the MCU Board and Main Drive Assy. Are P/J21 and P/J211 connected correctly? Go to step 6. Reconnect the connector(s) P/ J21 and/or P/ J211 correctly, then go to step 5. 5 Does the error still occur when the power is turned Off and On? Go to step 6. Complete. 6 Reseat the Main Drive Assy. Does the error still occur when the power is turned Off and On? Go to step 7. Complete. 7 Disconnect J21 from the MCU Board. Measure the voltages across J21-2/ J21-4 <=> ground on the MCU Board. Are the voltages about +24 VDC when the interlock switch (Interlock Harness Assy) is pushed? Replace the Main Drive Assy. Replace the MCU Board.