Causes: • Sub Drive Assembly (PL7.1.1) • MCU Board (SFP PL8.2.13; MFP PL8.3.6) • Sub Motor Harness Assy (PL9.1.8)
Remedy: 1 Does the error still occur when the power is turned Off and On? Go to step 2. Complete. 2 Reseat the Fuser Assy and Imaging Unit. Does the error still occur when the power is turned Off and On? Go to step 3. Complete. 3 In the Printer Diagnostic tests, use Engine Diag > Motor Test > Sub Motor FULL1. Does the Sub Motor function normally? Replace the MCU Board. Go to step 4. 4 Check the connections between the MCU Board and Sub Drive Assembly. Are P/J22 and P/J221 connected correctly? Go to step 6. Reconnect the connector(s) P/ J22 and/or P/ J221 correctly, then go to step 5. 5 Does the error still occur when the power is turned Off and On? Go to step 6. Complete. 6 Check the Sub Motor Harness Assy for continuity. Disconnect J22 from the MCU Board. Disconnect J221 from the Sub Drive Assembly. Is each cable of J22 <=> J221 continuous? Go to step 7. Replace the Sub Motor Harness Assy. 7 Reseat the Sub Drive Assembly. Does the error still occur when the power is turned Off and On? Go to step 8. Complete. 8 Check the power to the Sub Drive Assembly. Disconnect J22 from the MCU Board. Are the voltages across J22-2/J22-4 <=> ground on the MCU Board, about +24 VDC when the interlock switch (Interlock Harness Assy) is pushed? Replace the Sub Drive Assembly. Replace the MCU Board.