Code: 042-372, 042-373
Description: IOT K Mode Solenoid Error 1/2
Causes: • Feed Drive Assembly (PL7.1.4) • MCU Board (SFP PL8.2.13; MFP PL8.3.6)
Remedy: 1 Does the error still occur when the power is turned Off and On? Go to step 2. Complete. 2 In the Printer Diagnostic tests, use Engine Diag > Motor Test > K Mode Solenoid. During this check, close the Front Cover. Do you hear the K Mode Solenoid click when you perform the K Mode Solenoid? Go to step 3. Go to step 4. 3 Reseat the Feed Drive Assembly. Does the error still occur when the power is turned Off and On? Go to step 8. Complete. 4 Check the connection between the MCU Board and K Mode Solenoid. Is P/J24 connected correctly? Go to step 6. Reconnect the connector P/ J24 correctly, then go to step 5. 5 Does the error still occur when the power is turned Off and On? Go to step 6. Complete. 6 Disconnect J24 from the MCU Board. Is the voltage across P24-1 <=> ground on the MCU Board, about +24 VDC when the Interlock Switch (Interlock Harness Assy) is pushed? Go to step 7. Replace the MCU Board. 7 Disconnect P/J24 from the MCU Board. Measure the resistance between J24-1 and J24-2. Does the resistance measure about 80 to 110-ohm? Replace the MCU Board. Replace the Feed Drive Assembly. 8 Check the connections between the MCU Board and K Mode Sensor. Are P/J26 and P/J261 connected correctly? Go to step 10. Reconnect the connector(s) P/ J26 and/or P/ J261correctly, then go to step 9. 9 Does the error still occur when the power is turned Off and On? Go to step 10. Complete. 10 Disconnect J26 from the MCU Board. Is the voltage across P26-1 <=> ground on the MCU Board, about +3.3 VDC? Go to step 11. Replace the MCU Board. 11 Perform the procedure “K Mode Sensor” on page 4-24 to check the K Mode Sensor operation. Does the status (L or H) change when you insert a piece of paper into the gap of the K Mode Sensor? Replace the MCU Board. Replace the Feed Drive Assembly.