Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 061-370 — Xerox Phaser 6500

Code: 061-370

Description: IOT ROS Failure
Causes: • Laser Unit (PL4.1.1) • Laser RE Harness Assy (PL4.1.22) • Laser Video Harness Assy (PL4.1.23) • MCU Board (SFP PL8.2.13; MFP PL8.3.6)
Remedy: 1 Does the error still occur when the power is turned Off and On? Go to step 2. Complete. 2 Check after resetting the MCU Board. Reseat the MCU Board. Does the error still occur when the power is turned Off and On? Go to step 3. Complete. 3 Check after resetting the Laser Unit. Reseat the Laser Unit. Does the error still occur when the power is turned Off and On? Go to step 4. Complete. 4 Check the connections between the Laser Unit and MCU Board. Are P/J40, P/J41, P/J411 and P/J412 connected correctly? Go to step 6. Reconnect the connector(s) P/ J40, P/J41, P/ J411 and/or P/ J412 correctly, then go to step 5. 5 Does the error still occur when the power is turned Off and On? Go to step 6. Complete. 6 Check the Laser RE Harness Assy for continuity. Disconnect P/J40 from the MCU Board. Disconnect P/J411 from the Laser Unit. Is each cable of J40 <=> J411 continuous? Go to step 7. Replace the Laser RE Harness Assy. 7 Check the Laser Video Harness Assy for continuity. Disconnect J41 from the MCU Board. Disconnect J412 from the Laser Unit. Is each cable of J41 <=> J412 continuous? Go to step 8. Replace the Laser Video Harness Assy. 8 Check after replacing the Laser Unit. Replace the Laser Unit. Does the error still occur when the power is turned Off and On? Replace the MCU Board. Complete.

← Xem tất cả mã lỗi Xerox Phaser 6500

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie