Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 042-325 — Xerox Phaser 6600

Code: 042-325

Description: IOT Motor Failure Detect Motor Failure
Causes: • Main Motor [Drive Assembly] (PL3.1.1) • Drive Harness Assembly (PL18.2.2) • Top Harness Assembly (PL18.2.5) • LVPS (PL18.1.34) • MCU Board (PL18.1.13)
Remedy: 1 Check the Main Motor operation Execute Digital Output diagnostic test 071-001, and check the Main Motor rotation. Does the Main Motor function normally? Replace the MCU Board. Go to step 2. 2 Check the Main Motor connection Check the connection between the Main Motor and the LVPS, and the connection between the Main Motor and the MCU Board. Are P/J311, P/J509, P/J171 and P/J17 connected securely? Go to step 3. Connect P/J311, P/J509, P/J171, and P/J17 securely. 3 Check the continuity between the Main Motor and the MCU Board Is each cable of P/J171<=>P/J17 continuous? Go to step 4. Replace the Drive Harness Assembly. 4 Check the continuity between the Main Motor and the LVPS Is each cable of P/J311<=>P/J509 continuous? Go to step 5. Replace the Top Harness Assembly. 5 Check the power to the Main Motor (+24 VDC) Close the interlock switch(es), and check if the voltage between the LVPS ground and the P/J509-1 pin is about +24 VDC. Replace the Drive Assembly. Replace the LVPS.