Description: Black Patch Error IOT could not recovery toner density.
Causes: • Black Imaging Unit (PL8.1.5) • Black Toner Cartridge (PL5.1.11) • MCU Board (PL18.1.13)
Remedy: 1 Check after reinstalling the Toner Cartridge Pull out and shake the Black Toner Cartridge, and then reinstall it. Does the error still occur? Go to step 2. Finished. 2 Check after replacing the Toner Cartridge Replace the Black Toner Cartridge. Does the error still occur? Go to step 3. Finished. 3 Check the Imaging Unit installation Take out the Black Imaging Unit. Is the connection part of the Black Imaging Unit clean? And, is the Black Imaging Unit touching against the guides on the left and right sides, and installed properly? Go to step 4. Clean the contact point. Reinstall the Black Imaging Unit.