Mã lỗi 09-614-00, 09-631-00 — Xerox Phaser 6700

Code: 09-614-00, 09-631-00

Description: Fuser Envelope Lever is Up/Down The Envelope Mode Sensor indicates the Fuser’s envelope lever is in the wrong position for the media being fed. • 09-614-00 Fuser Envelope Lever is Up • 09-631-00 Fuser Envelope Lever is Down
Causes: • Envelop Mode Sensor PL7.2.10 • MCU Board, PL10.2.18 • Exit Harness, PL11.1.7
Remedy: 1 Remove the Fuser and check the envelope lever and actuator. The lever and actuator are undamaged. Go to Step 2. Replace the Fuser. 2 Test the Envelope Mode Sensor using dc330 (010-206). The signal changes (On/Off). Go to Step 3. Go to Step 4. 3 Check continuity of the Exit Harness between P/J20 on the MCU Board and P/J225 at the sensor. The harness is undamaged. Go to Step 4. Replace the Exit Harness. 4 Check for 3.3V at P/J20-1 on the MCU Board. Is 3.3V available at JJ20-1? Replace the Envelope Mode Sensor. Replace the MCU Board.