Description: CMYK Toner is Low or Empty The Toner CRUM indicates the Toner Cartridge is low or empty. • 09-624-00 Magenta Toner is Empty • 09-624-01 Magenta Toner is Empty • 09-624-02 Magenta Toner is Empty • 09-624-03 Magenta Toner is Empty • 09-624-04 Magenta Toner is Empty • 09-625-00 Yellow Toner is Empty
Remedy: • Replace the affected Toner Cartridge. • Cycle system power. • If the problem persists, follow the procedure below. 1 Reseat the indicated Toner Cartridge. The error persists. Go to Step 2. Complete. 2 Check connections between P/J11 on the MCU Board and indicated CRUM Connector: P/J204(Y), P/J205 (M), P/J206(C), P/J207 (K). The connection is secure. Go to Step 3. Secure the connection. 3 Check Toner CRUM Harness continuity between P/J11 on the MCU Board and indicated CRUM Connector: P/J204(Y), P/J205 (M), P/ J206(C), P/J207 (K). The harness is undamaged. Go to Step 4. Replace the Toner CRUM Harness. 4 Check for 2.5V at P/J11-3(Y), -7(M), - 11(C), -15(K) on the MCU Board. Is 2.5V available to the indicated Toner CRUM? Replace the affected Toner Cartridge. Replace the MCU Board.