Description: Finisher Failure - Stack Height Sensor 1 Stack Height Sensor 1 signal is not detected within the specified time after the Stacker Tray starts moving up.
Remedy: 1 Check Stacker Drive and belts for obstacles or wear. Are there obstacles or belt wear in the vertical transport mechanism? Remove obstacles or replace worn parts. Go to Step 2. 2 Test Stack Height Sensor 1 using dc330 (012-040). The sensor signal changes (On/Off). Go to Step 7. Go to Step 3. 3 With Stack Height Sensor 1 turned On in diagnostics, check for 5V at P/ J8873-1. Is 5 V available at P/J8873-1? Replace Stack Height Sensor 1. Go to Step 4 4 Check Finisher Main Board connection P/J8989. The connection is secure and undamaged. Go to Step 5. Secure the connection. 5 Check SNR2 harness continuity between P/J8989 and P/J8873. The harness is undamaged. Go to Step 6. Replace the harness. 6 With Stack Height Sensor 1 turned On in diagnostics, check for 5V at P/ J8989-6B on the Finisher Main Board. Is 5 V available at P/J8989-6B? Replace the MCU Board. Replace the Finisher Main Board. 7 Test the Stacker Drive using dc330 (012-026 Up, 012-027 Down). The Stacker Tray moves up and downs (On/Off). Go to Step 12. Go to Step 8. 8 Check MOT3 harness continuity between P/J8983 on the Finisher Main Board and P/J8891 on the Stacker Drive. The harness is undamaged. Go to Step 9. Secure the connections. 9 With the Stacker Drive turned On in diagnostics, check for 24V at P/ J8986-1 and -3 on the Finisher Main Board. Is 24V available at P/J8986? Replace the Stacker Drive. Go to Step 10. 10 Check for 24V at P/J8980-1 on the Finisher Main Board. Is 24V available at P/J8980-1. Replace the MCU Board. Go to Step 11. 11 Remove the Finisher LVPS harness and check continuity between P/ J591 on the LVPS and P/J8980 on the Finisher Main Board. The harness is undamaged. Replace the Finisher LVPS. Replace the harness. 12 Replace the Finisher Main Board. Does the error persist? Replace the MCU Board. Complete.