Description: CMYK Toner Failure A communication or CRUM data failure was detected in one of the Toner Cartridges. • 393.901.02 Black (K) Toner Cartridge communication error • 393.902.03 Black (K) Toner Cartridge data error • 393.903.02 Yellow (Y) Toner Cartridge communication error • 393.904.03 Yellow (Y) Toner Cartridge data error • 393.905.02 Magenta (M) Toner Cartridge communication error • 393.906.03 Magenta (M) Toner Cartridge data error • 393.907.02 Cyan (C) Toner Cartridge communication error • 393.908.03 Cyan (C) Toner Cartridge data error
Remedy: 1 Reseat the affected Toner Cartridge and cycle system power. Does the error persist? Go to Step 2. Complete. 2 Replace the affected Toner Cartridge. Does the error persist? Go to Step 3. Complete. 3 Check P/J11 on the MCU Board and toner CRUM connections P/J204(Y), P/J205(M), P/J206(C) and P/ J207(K). The connections are secure. Go to Step 4. Secure the connections. 4 Check continuity of the TN/CRUM Harness between the CRUM connections and P/J11 on the MCU Board. The harness in undamaged. Go to Step 5. Replace the harness. 5 Check for 2.5V at P/J11-3, -7, -11, and -15 on the MCU Board Is 2.5 V available at P/J11? Replace the Toner CRUM Connector Assy. Replace the MCU Board.