Remedy: 1 Check the Feed and Separator Rollers for contamination, wear or damage. The rollers are clean and undamaged. Go to Step 2. Replace the rollers. 2 Test the Registration Sensor using dc330 (10-202). The signal changes (On/Off). Go to Step 4. Go to Step 3. 3 Check for 3.3V at P/J10-7 on the MCU Board. Is 3.3 V available at P/J10-7 when the Front Interlock Switch is closed? Replace the Registration Sensor. Replace the MCU Board. 4 Test the Feed Drive Motor Alarm using dc330 (10-204). The signal changes (On/Off). Replace the Feed Drive Assy. Go to Step 5. 5 Test the Take Away Clutch using dc330 (72-008) The clutch signal changes (On/Off). Go to Step 7. Go to Step 6. 6 Check for 24V at P/J10-5 and -10 on the MCU Board. Is 24 V available at P/J10-5? Replace the Take Away Clutch. Replace the MCU Board. 7 Test the Feed Clutch using dc330 (72-007) The clutch signal changes (On/Off). Go to Step 8. Go to Step 9. 8 Check for 24V at P/J10-3 on the MCU Board. Is 24 V available at P/J10-3? Replace the Feed Clutch. Go to Step 9. 9 Replace the MCU Board. The error persists. Visually inspect and test continuity of all applicable harnesses. Complete.